Bionics Corporation.

Patient Monitor

Contact Now* Send an Inquiry to this supplier.
or
Start Order * Name your price

Browse by Category

Contact us

Bionics Corporation.
[Korea]

Address
1406 Masters Tower 553 Dohwadong  Mapo-gu, Seoul
Phone
82-2-7142962
Contact name
Dae-seong, Kim

Quick Information

  • Model Number : Matron

Description

Patient Monitor

Patient Monitor is measuring and monitoring related to patient-hearts such as electrocardiograph waves, respirations, pulses, blood pressure and degree of saturation of oxygen.

Matron

It is ALL in your handgrip, NIBP, IBP, SpO2, ECG, Respiration, Temperature, Battery operation and Stress-free data scrolling functions but a few...

Take it to the Limit.
Protable design and features with an easy-grip handle. Battery operation keeps you mobile anytime, any where.

Full Specification

Display

  • Screen : 10.4" color TFT LCD
  • Resolution : 640 x 480
  • Trace : 6 Max.
  • Sweep Speed " 603 /12.5 / 25 / 50mm/s
  • Indicator : AC power LED, Battery charging LED
  • Alarm suspend LED, Alarm LED

ECG

  • Input : 5-lead (I, II, III, aVL, aVR, aVF, V)
  • ECG waveform : 1Channer (the 2nd waveform cascade)
  • 2Channer (Optional)
  • Sweep speed : 6.3 / 12.5 / 25 / 50mm/s
  • Gain (Sensitivity) : 5 / 10 / 15mm/mV
  • Pulse range : 20 to 300bpm
  • Pulse accuracy : ±2bpm
  • Lead-off Detection : Yes
  • Arrhythmia Analysis : Yes
Respiration

  • Measurement range : 0~150bpm
  • Resolution : 1rpm
  • Accuracy : ±2rpm
  • Apnea delay : 10~40 sec (in 5 sec. Steps)

NIBP

  • Technique : Oscilometric
  • Operation mode : manual
  • Automatic (2/5/10/15/30/60/120min)
  • Inflation pressure range : 0-300mmHg
  • Inflation pressure Max : Adult : 300 ±5mmHg
  • Neonate : 150 ±5mmHg
  • Resoluction : 1mmHg
  • Over-pressure protection : Yes
  • Adult : Systolic(60-270), Diastolic(40-245), Mean(45-255)
  • Neonate : Systolic(50-130), Diastolic(30-100), Mean(40-120)

SpO2

  • Measurement range : 20-100%
  • Measurement range accuracy : ±2%
  • Pulse rate range : 20-300bpm
  • Pulse rate accuracy : ±2bpm
  • SpO2 accuracy : ±2% (70-100%), ±3% (50-69%), 0-49% Unspecified
  • Resolution : 1%

IBP (2 IBP / optional)

  • Measurement range : -40 to 360mmHg
  • Channel : 2 channel
  • Resolution : ±1mmHg
  • Accuracy : ±2mmHg
  • Auto zero balancing range : ±20mmHg
  • Alarm Range : -40 to 360mmHg

Temperature(2 Temperature)

  • Measurement range : 10~45°C
  • Accuracy : 0.1°C

EtCO2 (optional)

  • Measurement mode : Microstream
  • Range :0~99mmHg
  • Accuracy :
    0~38mmHg ±2mmHg
    39~99mmHg ±5%+0,08%
  • for every 1mmHg above 38mmHg
  • Respiration rate : 0~150 breaths per minute
  • Respiration accuracy :
    ±1breaths per minute from 0~70bpm
    ±2bpm from 71~120bpm
    ±3% from 12~150bpm
  • CO2 waveform
  • Recognition : 5mmHg ±2mmHg bandwidth
  • Start-up time : 30seconds typical
  • Sampling rate : 50ml/minute ±7.5ml/min
  • Auto zero : <15seconds at 5, 10, 15 and 60minute then every 60minutes thereafter.


Product Image

  • Patient Monitor image

Send an Inquiry to this supplier

Send an Inquiry to this supplier
* From
  To Dae-seong, Kim
Bionics Corporation.
* Buying Product
- Please enter your specific buying item.
e.g. 42 inch LCD TV, leather executive chair
Category : Heart Rate Monitor
* Message

Use English only Max. 2000 characters. (Min. 20)

Send
EC21.com does not guarantee the validity of product information or the credentials of sellers.

Browse: Manufacturer Directory Premium Suppliers Site Map

About EC21 Contact Us Terms & Conditions Report Item Online Trading Risks Product Listing Policy

Copyright (c)1997-2026 EC21 Inc. All Rights Reserved. EC21 in KoreanChinese

Business Registry Number: 120-86-03931 | Mall order sales Registration Number: 강남-5838